Sewage Chemicals Treatment-40

Corroision Inhibitor for Closed Chilled Systems Concentrate

Product Description | Product Application | Product Notes| Product DOSE
Nitrite based closed circuit inhibitor 1000ppm at 0.26%
Code:
RXSOL-40-4036-025
Other Equivalent Brand

Accepta 2532

Short Description:
Multi-functional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems RXSOL-40-4021 is a high performance nitrite based closed circuit inhibitor with indicator
Corroision Inhibitor for Closed Chilled Systems Concentrate
Application:
RXSOL-40-4021 treatment is an effective corrosion inhibitor for ferrous metals in marine circulating cooling water systems. Because certain aluminum alloys are highly anodic, they may be difficult to [+] Read More...
Using Procedure:
The system should be filled with good quality fresh or distilled water and where freeze protection is necessary, the proper amount of glycol-based antifreeze should be added. Begin circulating the system wat [+] Read More...
Note:
Features Benefits Effective corrosion inhibitor Protects ferrous and non-ferrous metals Minimizes metal oxide deposits [+] Read More...
Technical Specifications:

Appearance

Light yellow liquid

Specific Gravity at 25° C (77° F)

1.3

Flash Point (PMCC)

None

pH, Neat

>10

Freeze Point:

-12.2° C (10° F)

Freeze/Thaw Stability

Complete

Remarks:

Corroision Inhibitor for Closed Chilled Systems Concentrate manufacturer and supplier in Mumbai, Fujairah, Muscat, Nairobi, Kandla, Kolkata, Chennai, Vizag, Gandhidham, Dubai, Sharjah, Ajman, Abudhabi, Barka Sohar Oman, Nairobi Kenya Africa, Sudan, Yemen

Corroision Inhibitor for Closed Chilled Systems Concentrate
Corroision Inhibitor for Closed Chilled Systems Concentrate
:
Packing Size:
1000.00 Ltr.
Available Packing Size:

Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Corroision Inhibitor for Closed/Chilled Systems with Nitrite & Indicator

Product Description | Product Application | Product Notes| Product DOSE
Nitrite based closed circuit inhibitor 1000ppm at 0.50% multi-functional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems
Code:
RXSOL-40-4020-025
Other Equivalent Brand

Accepta 2532, REMIDOL 1541

Short Description:
Corroision Inhibitor for Closed/Chilled Systems with Nitrite & Indicator
Corroision Inhibitor for Closed/Chilled Systems with Nitrite & Indicator
Application:
RXSOL-40-4020 treatment is an effective corrosion inhibitor for ferrous metals in marine circulating cooling water systems. Because certain aluminum alloys are highly anodic, they may be difficult to [+] Read More...
Using Procedure:
The system should be filled with good quality fresh or distilled water and where freeze protection is necessary, the proper amount of glycol-based antifreeze should be added. Begin circulating the system wat [+] Read More...
Note:
Features Benefits Effective corrosion inhibitor Protects ferrous and non-ferrous metals Minimizes metal oxide deposits [+] Read More...
Technical Specifications:

Appearance

Light yellow liquid

Specific Gravity at 25° C (77° F)

1.23

Flash Point (PMCC)

None

pH, Neat

12.3 - 12.9

Freeze Point:

-12.2° C (10° F)

Freeze/Thaw Stability

Complete

Remarks:

Corroision Inhibitor for Closed/Chilled Systems with Nitrite & Indicator manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Corroision Inhibitor for Closed/Chilled Systems with Nitrite & Indicator at a competitive price from us. We have ready stock of Corroision Inhibitor for Closed/Chilled Systems with Nitrite & Indicator in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Corroision Inhibitor for Closed/Chilled Systems with Nitrite & Indicator
:
Packing Size:
25.00 Ltr.
Available Packing Size:

HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

One Shot Universal Liquitreat 100

Product Description | Product Application | Product Notes| Product DOSE
Boiler Water treatment specialized is a well - balanced blend for boiler water treatment products, Resulting in a scale and corrosion control by one shot operation. A one-step treatment to control the [+] Read More...
Code:
RXSOL-50-5001-025
Other Equivalent Brand

RXSOL BWT LIQUID PLUS, Care Treat 3 Boiler 2, Drew Ameroid, Arboiler WT, BWT 104P Nor chem, B.W.T. NEW FORMULA EQUAL TO DREW - AGK 100, DM-511, EAZY BWT-1, MAXTREAT-3222, ONE SHOT BWT 25 Ltr

Short Description:
A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners
Generic Name:
BOILER scale and corrosion control by one shot operation
Active Matter:
54-60
One Shot Universal Liquitreat 100
Application:
The dosage rate is dependent on bioler operating condition, feed 2-3 ltrs of RXSOL-50-5001-025 solution for per thousand ltr of bioler water then control the system by periodic Alkalinity test procedu [+] Read More...
Using Procedure:
Control is by simple  boiler water tests or RX CLEANSERS  can provide a suitable test  kits for this purpose. Used in low pressure and auxillary boilers :::::::::::::::::::::Alkalinity  TEST FOR BOILER & [+] Read More...
Note:
Technical Specifications:

Boiler Water Treatment products

CHARACTERISTIC :

  • Convenient liquid treatment, which provides the basic alkalinity on which successful water treatment depends.
  • Provides optimum conditions for hardness control to function.
  • Neutralizes acid conditions.
  • Will assist in keeping silica in suspension.
  • Simple test to determine level of treatment.
  • Can be used in boilers of all pressures.
  • Can be used as a neutralizer after acid cleaning operations
  • Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.
  • Dispersant action suspends sludge and sediment particles for efficient blow down.
  • Oxygen scavenging for optimum protection.
  • Protects boiler, steam lines, condensate lines and feed water lines from corrosion.
  • Fast action due to catalyst.
  • Simple test to determine level of treatment.
Remarks:

Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce COin steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Chemical feed should be continuous. Chemical pumping rates can create problems especially for neat feed set ups. Using on/off feed systems such as a recycle timer can create problems. Chemical feed pumps should be sized or product strengths should be adjusted to allow continuous feed.

Steam and carbon dioxide leave continuously, so setting up a neutralizing amine pump to feed intermittently can lead to wide variations in condensate pH control. If sampling is done from a condensate receiver, the tank volume may buffer the variations and the changes may not be noticed, but corrosion could be occurring to areas of the piping that see the rapidly changing pH.


If polymeric dispersants, phosphonates, phosphate, or chelants are fed intermittently into the feedwater using a recycle timer, and the amines are not fed continuously, a cycle of iron slugs returning in the condensate can be followed by slugs of high dispersancy cleaning of the iron from the deaerator and dragging it into the boiler.

Load changes can affect chemical concentrations when the chemical feed is base fed. Example: Steam production of one million lbs./day; 4% blowdown; 20% active boiler polymer product fed at 5 pounds per day. The calculated daily average polymer concentration would be 24 ppm. Assume peak plant production load is 60,000 lbs./hr., but during the overnight hours the load is only 5,000 lbs./hr. If the dispersant is being fed continuously over the 24 hours, during the 8- hour low load period, the boiler polymer concentration would have increased to over 200 ppm. Upon high fire when production resumes, carryover is very possible because of over concentrating the polymeric dispersant.

Chemical feed needs to be paced to steam production, especially where significant load changes occur.

Carbon dioxide can concentrate in steam and condensate making neutralizing amine treatment impractical. Carbon dioxide levels can be relatively low in steam exiting a boiler at only a few ppm, but if there are areas where it becomes “trapped” and can accumulate, concentrations can reach extremely high levels into the hundreds or even thousands of ppm.

CO2 is a non-condensable gas. It has a distribution ratio in the steam piping and condenses at points throughout the system. At the boiling point, the solubility of the gas in water is extremely low. The solubility of the CO2 is actually lower in the condensate than it is in the steam. For the CO2 to escape from the steam into the water it will accumulate in the steam space just above the water level until the partial pressure becomes high enough for the CO2 in the incoming steam to be able to exit into the condensate. This creates a steady state condition of CO2 coming in and exiting, but an area of severe localized corrosion occurs where the carbon dioxide concentration is high.

The highest CO2 concentration normally occurs just above the condensate water level. If there is an area where condensation is occurring and running down pipes or the sides of vessels, the CO2 concentration will be very high and the pH will be about 5.3 – 5.5 in that location creating high corrosion rates.


The solubility of CO2 increases dramatically as the condensate temperature falls below 212 °F. When there is an accumulation of CO2 in an area and the condensate temperature is relatively low, the amount of carbon dioxide going into solution will be extremely high. Where low-pressure steam is used that contains CO2 and the heat exchange process has relatively close temperature differentials between the steam and the condensate, there is potential for high uptake of the CO2 into the condensate and localized low pH.

Neutralizing amines are selected in an effort to condense in the right concentrations to carbon dioxide condensation levels throughout the steam system. Neutralizing amines cannot control corrosion where this localized accumulation of carbon dioxide occurs since the high CO2 overwhelms the demand for the amine. Even point source addition of amine may not be able to satisfy the demand.

Where the concentrating effect of CO2 occurs, methods of reducing the problem include eliminating or minimizing CO2 in the steam, venting off the CO2 in the localized area, eliminating condensate in the area, applying a filming amine or metal passivator, or using higher temperature steam and increasing condensate temperature to reduce the CO2 content in the condensate.

#BoilerWaterTreatmentCHEMICAL_supplierDUBAI
#BoilerWaterTreatmentCHEMICAL_supplierMUSCAT
#BoilerWaterTreatmentCHEMICAL_supplierMUMBAI
#BoilerWaterTreatmentCHEMICAL_supplierNAIROBI

A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners. which resulting in a scale and corrosion control by one shot operation.

Boiler water treatment speacialized chemical products One Shot Universal Liquitreat  Exporter, manufacturer, supplier in Mumbai, Gandhidham - Kandla, Mundra, Sikka, Surat, Kolkata - Haldia, Buz Buj, Paradip, Visakhapatnam - Gangavaram, Fujairah, Dubai, Sharjah, Abu Dhabi, Ruwi Barka Muscat Sohar, Oman, Sudan, Yemen, Nairobi Kenya

BOILER WATER TREATMENT chemicals manufacturer and supplier in INDIA, MUSCAT OMAN, UAE DUBAI, Nairobi

One Shot Universal Liquitreat 100
One Shot Universal Liquitreat 100
One Shot Universal Liquitreat 100
:
Packing Size:
25.00 Ltr.
Available Packing Size:
ONE SHOT Boiler water treatment chemical products to control scale and corrosion inhibitors, oxygen scavengers, and sludge conditioners available in 25, 50, 210 Ltr HMHDPE Barrel.
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

ETHYLENE GLYCOL

Product Description | Product Application | Product Notes| Product DOSE
ETHYLENE GLYCOL  supplier and exporter. Its INDUSTRIAL GRADE Recommended to use as industrial chemicals; antifreezing agent, monomer solvent. 
Code:
RXSOL-19-1182-210
Other Equivalent Brand

1,2-Ethanediol, TYFOCOR Antifreeze and anti-corrosion fluid for thermotechnical systems

Short Description:
ETHYLENE GLYCOL - INDUSTRIAL GRADE - Recommended use: industrial chemicals; antifreezing agent
Generic Name:
1,2-Ethanediol Antifreeze and anti-corrosion fluid
IMPA Code:
550907,550908
ETHYLENE GLYCOL
Application:
Using Procedure:
Clear, Colourless, Syrupy liquid which lowers the freezing point of water. odorless and soluble in water, alcohol and acetone. Hazard: Toxic by ingestion and inhalation. Used as a coolant antifreeze, asphalt emulsion paint, heat transfer agent, brake fluid, solvent, or foam stabilizer.
Note:
Technical Specifications:
PRODUCT NAME  : ETHYLENE GLYCOL,  Di-ethylene glycol(Ethane 1-2 Diol)
CAS number  : 107-21-1
Form Phase   : Liquid
Colour : clear
Formula   : CH2OHCH2OH
Odour    : ODOURLESS
Solubility in water    : COMPLETE
Density    : 1.11 at 20 oC
Boiling point       : 197      oC
Melting point    : -13  oC
Flash Point    : Not Applicable
Ignition Temperature : 410  oC
Explosive limits   : Product does not present an explosion hazard.
Vapour pressure   : .07 mbar at 20 oC
Skin absorption/irritation  : YES
TLV       Country  NL                Year  1995  : 10 ppm                 26        mg/m3
Pollution category    1994 : D
 
Solubility in / Miscibility with water at 20°C : Fully miscible. g/l (Fully miscible.)
     

ETHYLENE GLYCOL manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of ETHYLENE GLYCOL at a competitive price from us. We have ready stock of ETHYLENE GLYCOL in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

ETHYLENE GLYCOL
:
Packing Size:
220.00 Kg.Liq
Available Packing Size:
20, 25, 50, 220 Kg. Also used as Antifreeze and anti-corrosion fluid for thermotechnical systems.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

RXSOL 2100

Product Description | Product Application | Product Notes| Product DOSE
  Diesel Locomotive Cooling System Treatment  
Code:
RXSOL-40-4037-210
Other Equivalent Brand
Nalprep 2001
Short Description:
unique liquid cleaner designed to clean Radiator and cooling water system of Contaminted ions, scale and oxide deposits while the engine is in operation.It removes oil, grease, dirt and loose metal oxide deposits. It can be used in all types of engines. I
RXSOL 2100
Application:
Application : RXSOL 2100 functions as a protective film-forming corrosion inhibitor and scale-suppressant to keep engines clean and free from over-heating, reducing downtime and maintenance costs. RXS [+] Read More...
Using Procedure:
Dose:  Properly clean the system with water and alkaline liquid , if necessary. Add 0 .15-1.5 % of RXSOL 2100 in system or recommended Nitrite level 1400 – 2500 ppm can be measured and controlled by any stan [+] Read More...
Note:
Future & Benefit : Liquid product, easy to use. By forming an oxide film on the metal surfaces electrolytic corrosion is prevented. Effective against cavitation and erosion. Compatible with [+] Read More...
Technical Specifications:

Physical Properties : 

Physical State : Liquid
Appearance : Dark Red
Odor : Mild
Ph (100 %) : 11.2 - 12 Astm E-70
Vapor Pressure : No Data Available.
Vapor Density : No Data Available
Specific Gravity : 1.17 - 1.2 (15.6 °C)
Density : No Data Available
Solubility In Water : Complete
Melting Point : No Data Available
Remarks:

RXSOL 2100 manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of RXSOL 2100 at a competitive price from us. We have ready stock of RXSOL 2100 in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

RXSOL 2100
:
Packing Size:
210.00 Ltr.
Available Packing Size:
10 Ltrs, 25 Ltrs, 210 Ltrs
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Scale Corrosion Inhibitor Open - closed cooling systems

Product Description | Product Application | Product Notes| Product DOSE
RXSOL-40-4022-210 is a high performance, low toxicity molybdate based cooling water corrosion inhibitor scientifically formulated for the treatment and protection of open and closed cooling water syst [+] Read More...
Code:
RXSOL-40-4022-210
Other Equivalent Brand

Accepta 2508

Short Description:
Scale & Corrosion Inhibitor for open and closed cooling systems (ECO)
Scale Corrosion Inhibitor Open - closed cooling systems
Application:
Using Procedure:
Application & Dosage Information RXSOL-40-4022-210 should be dosed to give 100 – 150 ppm for open systems and 1000 – 1500 ppm for closed systems.It is important when starting up a new system or re-starting [+] Read More...
Note:
Product Benefits:   High performance, low toxicity molybdate corrosion inhibitor Excellent corrosion control for steel, copper and brass Contains an effective dispersant Low toxicity [+] Read More...
Technical Specifications:

 

Product        Properties 
Form:  Liquid
Colour: Pale orange
Odour:  Barely perceptible odour
pH:  12.0 – 14.0
Relative density: Relative density:
Solubility in water:  Miscible in all proportions

 

Scale and Corrosion Inhibitor for Cooling Water Treatment manufacturer and supplier in Mumbai, Muscat Oman, Fujairah UAE Middle East, Kolkata, Chennai, Visakhapatnam, Kandla, Gandhidham, Navi mumbai MIDC, Dubai, Sharjah, Ajman, Abudhabi

Scale Corrosion Inhibitor Open - closed cooling systems
:
Packing Size:
210.00 Ltr.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

L GLUTAMIC ACID

Product Description | Product Application | Product Notes| Product DOSE
Glutamic acid is an amino acid used to form proteins. In the body it turns into glutamate. This is a chemical that helps nerve cells in the brain send and receive information from other cells.  Glutamic acid may be involved in learning and memory.
Code:
RXSOL-60-6604-824
Other Equivalent Brand

L GLUTAMIC ACID food supplement

Short Description:
L GLUTAMIC ACID
Generic Name:
L GLUTAMIC ACID food supplEment
L GLUTAMIC ACID
Application:
Glutamic acid often is used as a food additive and flavor enhancer in the form of its sodium salt, known as monosodium glutamate (MSG).
Using Procedure:
Glutamic acid is an amino acid used to form proteins. In the body it turns into glutamate. This is a chemical that helps nerve cells in the brain send and receive information from other cells. It may be involved in learning and memory.
Note:
The relatively high glutamate levels in some traditional diets suggest that it is a safe food additive. However, anecdotal and scientific evidence indicates that high levels of glutamate and MSG consumption cause adverse health effects.
Technical Specifications:
Remarks:
1.Improve Memory and Focus
Glutamic acid works as a fuel for the brainGlutamic acid helps nerve cells send messages and receive information from cells.  low levels of glutamine. A glutamine deficiency is thought to cause symptoms like insomnia, low energy, and mental exhaustion.  
 
2. Support Prostate Health
Glutamic acid is essential for proper functioning in the prostate. As men age, it’s common for the prostate glands to start to increase in size. The medical name for this condition is prostatic hyperplasia (BPH). xperts often recommend glutamic acid supplements for prostate health to reduce symptoms of BPH.
 
3. Glutamic acid /  glutamine supplements prevent muscle breakdown.
 
Plant-based sources of glutamic acid:
 
Hemp seeds 
Beans, lentils, and peas
Green tea
Amaranth and Quinoa 
Brown rice
Spirulina
Oatmeal
L GLUTAMIC ACID  manufacturers, suppliers, exporters in Mumbai, Gandhidham, Kolkata, Varanasi, Visakhapatnam, Chennai, Fujairah, Dubai, Canada BC, Barka, Sohar, Muscat, Oman.
Lab chemicals manufacturers, suppliers, exporters in India, UAE Middle East, Barka, Sohar, Muscat, Oman, Canada.
 
L GLUTAMIC ACID  is available in small packing as well as in bulk. Buy premium quality L GLUTAMIC ACID and other lab chemicals from one of the most trusted brands.
L GLUTAMIC ACID
:
Packing Size:
25.00 Kg.PWD
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Antifreeze with Potassium Chromate

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-60-6236-100
Other Equivalent Brand

Potassium Chromate Solution with Antifreeze

Short Description:
pH control and water softening ability. Potassium dichromate is added to antifreeze-antiboil as a corrosion inhibitor. The pH control is used to maintain an acid free solution. The water softening ability deters formation of mineral deposits Inhibitor systems are available in various forms such as
Antifreeze with Potassium Chromate
Application:
Antifreeze with Potassium Chromate solution is most popular antifreeze to add in chilled water for prevention of ice formation. In general  GLYCOL only prevent formation of ice in chiller water system [+] Read More...
Using Procedure:
Note:
Technical Specifications:

Remarks:

Antifreeze with Potassium Chromate manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Antifreeze with Potassium Chromate at a competitive price from us. We have ready stock of Antifreeze with Potassium Chromate in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Antifreeze with Potassium Chromate
:
Packing Size:
25.00 Ltr.
Available Packing Size:
5, 20, 25, 50, 210 Ltr
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

KARL FISCHER REAGENT Pyridine Free

Product Description | Product Application | Product Notes| Product DOSE
The pyridine-free Karl Fischer reagent consists of two solutions, a dissolving agent and a titrating agent. The dissolving agent contains sulfur dioxide and a pyridine substitute in a solvent and is used for taking up the sample to be investigated with respect to its water content.
Code:
RXSOL-60-6604-769
Other Equivalent Brand

KARL FISCHER REAGENT Pyridine Free

Short Description:
KARL FISCHER REAGENT Pyridine Free
Generic Name:
Titrators For Accurate Karl Fischer Water Determinations
KARL FISCHER REAGENT Pyridine Free
Application:
An essentially pyridine-free Karl Fischer reagent useful in the determination of water, comprising a dissolving agent containing sulfur dioxide and a pyridine substitute in a Karl Fischer solvent, an [+] Read More...
Using Procedure:
Karl Fischer Reagent (Pyridine free). single soln for titrimetric determination of water 1 ml reagent ~5 mg water.
Note:
The analysis of the water content of a sample by Karl Fisher titration can be carried out using a volumetric method or a coulometric one.
Technical Specifications:
Remarks:
Karl Fischer titration is simply a method for quantifying water content of samples. The fundamental principle behind this reaction is based on the Bunsen reaction between compounds such as iodine, sulphur dioxide to form sulphuric acid and hydrogen iodide. Karl Fischer initiated a new method based on Bunsen’s reaction. He discovered that the reaction could be modified for determining water in a non-aqueous system containing an excess of sulphur dioxide in the presence of a suitable base. He used a primary alcohol (methanol) as the solvent and a base (pyridine) as the buffering agent.
 
What is the Karl Fischer Reaction?
(1) CH3OH + SO2 + RN [RNH]SO3CH3
 
Reaction-1:  is where the alcohol reacts with sulphur dioxide (SO2) and base to form an intermediate alkylsulfite salt
 
(2) H2O + I2 + [RNH]SO3CH3 + 2RN [RNH]SO4CH3 + 2[RNH]I
 
Reaction-2: is the oxidation step where the intermediate is then oxidised to an alkylsulphate salt. This reaction consumes water.

Water and iodine are consumed in a 1:1 ratio. Once all of the water present is consumed, the presence of excess iodine is detected by the indicator electrode. That signals the end-point of the titration. The amount of water present in the sample is calculated based on the concentration of iodine in the Karl Fisher titrating reagent and the amount of Karl Fisher Reagent consumed in the titration. Depending on the type of base used the rate of reaction will vary. Classic Karl Fischer reagents contained pyridine, a noxious carcinogen, as the base. Due to its weak basicity the reaction is slow and the end point is not stable. The most common base used today is imidazole where greatest accuracy and repeatability can be achieved. Coulometry is an absolute technique so standardisation of Karl Fischer reagents is not necessary.
 
 
Coulometric Titration Method
In coulometric Karl Fischer, iodine is generated electrochemically in situ during the titration.
The anolyte contains iodide, sulphur dioxide, bases and solvents such as methanol. Electrolytic oxidation occurs when a sample is added to this anolyte.
Iodine is generated at the anode of the titration cell as shown in formula (3)
(3) 2I--2e ---> I2
Stoichiometrically, 1 mole of water will react with 1 mole of iodine, so that 1 milligram of water is equivalent to 10⋅71 coulombs of electricity
Comparison of volumetric and coulometric titration cells.
 
In the volumetric technique, which is used to determine higher water contents generally at levels above 5%, the iodine is introduced via a burette or similar dosing system. For lower water content detection, down to ppm levels, the coulometric technique produces the iodine
in-situ by electrolysis. Coulometry improves the Karl Fischer technique by removing the need for reagent calibration and
provides an absolute result in micrograms of water.

Low reagent usage: multiple samples can be analysed with a single charge of reagent which means less waste and less handling of chemicals, good news for Health and Safety
 
 
 Karl Fischer KF Reagent

Karl Fischer KF Reagent A is a general coulometric KF anolyte for use with generator electrodes which incorporate a frit or diaphragm to separate the anode and cathode chambers. Used in conjunction with Reagent C this formulation is supplied in a pack of 8 x 100ml bottles, 8 x 5ml cathode vials, all conveniently located in a single carton.

To conform to ASTM, API, EI, ISO (plus others) methodology for water content determination of oil and petroleum products, the anode regent must be modified with xylene to improve sample solubility and miscibility. Karl Fischer KF Reagent is pre-mixed with xylene, and other solubilizers to eliminate side reactions, so that the operator does not have to store or mix chemicals.

 
 
 
Karl Fischer KF Reagents combine speed and accuracy
VOLUMETRIC COULOMETR K.F. Titration Cell Differences
• Single shot bottles
• Safer to use
• Safer to store
• Low cost
• Faster precondition
• Reduced downtime
• Improved sample miscibility / solubility
• For use with all coulometers
[KARL FISCHER REAGENT Pyridine Free] manufacturers, suppliers, exporters in Mumbai, Gandhidham, Kolkata, Varanasi, Visakhapatnam, Chennai, Fujairah, Dubai, Canada BC, Barka, Sohar, Muscat, Oman.
Lab chemicals manufacturers, suppliers, exporters in India, UAE Middle East, Barka, Sohar, Muscat, Oman, Canada.
 
[KARL FISCHER REAGENT Pyridine Free] is available in small packing as well as in bulk. Buy premium quality [KARL FISCHER REAGENT Pyridine Free] and other lab chemicals from one of the most trusted brands.
KARL FISCHER REAGENT Pyridine Free
:
Packing Size:
1.00 Bottle
Available Packing Size:
Titrators For Accurate Karl Fischer Water Determinations
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

pH Booster

Product Description | Product Application | Product Notes| Product DOSE
Boiler Alkaline Builder RXSOL pH Boosters are liquid  alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.
Code:
RXSOL-40-5024-025
Other Equivalent Brand

MAXTREAT - 3006, Boiler Water Treatment Alkalinity Builder 25 Ltr, HYDREX 1565

Short Description:
Boiler Alkaline Builder RXSOL pH Boosters are liquid alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.
Generic Name:
Boiler Alkaline Builder
Active Matter:
63
pH Booster
Application:
Using Procedure:
RXSOL  pH Boosters are dosed depending upon the feed water characteristic and alkalinity requirement. It is compatible with all other treatment chemicals. It is dosed exactly as per the dosage rate and method of RXSOL-50-5001-025
Note:
Key Features & Benefits:- Minimizes corrosion of feed water tank, lines and pump Imparts water and sludge conditioning to minimize scaling and deposition Compatible with other treatment Chmicals Completely biodegradable chemicals
Technical Specifications:

 

Properties Unit Typical Value
Form and Appearance - Clear Colorless Liquid
Odor - Characteristic
pH (neat) pH Alkaline
Solubility - Completely Soluble in Water
Remarks:

pH booster manufacturer supplier exporter in Mumbai Kandla Kolkata Chennai Vishakhapatnam Fujairah Muscat Kenya Canada. Get best price of pH booster. International standards of pH booster in ready stock in India UAE Oman Africa.

pH Booster manufacturer and supplier in Mumbai, Ganhdidham - Kandla, Mundra, Sikka, Kolkata, Buj Buj, Haldia, Paradip, Chennai - Ennore, Visakhapatnam, Gangavaram, Surat, Fujairah, Dubai, Sharjah, Abu Dhabi, Oman.

pH Booster
pH Booster
:
Packing Size:
25.00 Ltr.
Available Packing Size:
25 Kgs. 50 Kgs.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products

 

Mail Us for any PRODUCT related information and purchase inquiry : rxmarinechemical@gmail.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarinechemical@gmail.com ( This mail is for supplier only )

 

 

Syndicate content